DSH Seals sort out some general problems of dynamic seals as below.
Too much leakage
Reasons and measures,
1 Poor assembly; install the seals in correct method, do not reverse or dislocation
2 Lake of pressure on the lip of oil seals; check the correct size of the seal and spring working properly
3 Rod surface finish or scraches; reduce the roughness of the shaft, select soft material or other seals material
4 Seal lip cracking; maybe due to the rough surface of the shaft, incorrect seals material or speed, high
temperature
5 seals are damaged or worn; replace seals and improve wear resistance performance
Large friction
Reasons and measures,
1 Poor lubrication; may be changed to polytetrafluoroethylene friction surface
2 Large preload; change seals types
3 Large pressure; change seals types
Seals are damaged
Reasons and measures,
1 Improper installation or careless; use appropriate technology and tools
2 Rough shaft; see the surface roughness and chamfering technical requirements
3 There are abrasive particles; choose dust seals in a dusty environment
Too much wear
1 improper seals type or material; choose the right seals according to the working condition
2 High temperature, choose the right seals according to the working condition
3 High pressure, choose the right seals according to the working condition
DSH Seals can offer sealing solution based on your actual working condition, welcome to contact us.